ET 101 - CEMS
Slide title
Write your caption hereButtonSlide title
Write your caption hereButton
Opacity Monitor
Used for non-compliance applications, the ET101/102 is a simple, reliable, cost effective way to measure opacity or dust in a stack or duct.
-
DESCRIPTION
The ET101/102 Opacity Monitor is a single-pass transmissometer consisting of visible light transmitter and receiver arrangement with digital data processing in a local display unit. The monitors can display data in opacity, extinction or dust density in mg/m3 or normalized dust density in mg/Nm3.
Using analog inputs from a process, the ET102 offers normalization of the opacity data from temperature, oxygen, pressure and water vapor.
-
FEATURES
- Simple instillation for low initial cost
- Proven technology offers low maintenance and high reliability
- High-efficiency air purges minimize lens contamination
- Data in percentage opacity, mg/m3, mg/Nm3 dust for optimum flexibility
-
PARAMETERS
Operating Principle
- Single pass transmissometer
Light Source
- Modulated high-intensity LED at 637 nm wavelength
Span
- Fully selectable in % opacity, extinction, mg/m3 & mg/Nm3
Averaging
- 4 rolling averages selectable from 10 secs to 30 days
Accuracy
- ±0.2% opacity
Drift
- <1% opacity per month
Resolution
- 0.1% opacity
Optical Path Length
- 1.6 feet - 49 feet
-
DATASHEET
Brochure and Manual availibe on the Downloads page here.